JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs
JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs
JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs
JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs
JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs
JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs

JBP Nano Cannula 22G x 50 mm | Blunt Microcannulas + Pre-Puncture Needles | 24 pcs

JBP Nano Cannula 22G x 50 mm are sterile blunt disposable cannulas with an ultra-thin wall design for professional use by qualified personnel. The pack contains 24 blunt microcannulas 22G x 50 mm and 24 matching pre-puncture needles 21G x 25.4 mm.

Contents: 24 sterile blunt disposable cannulas + 24 pre-puncture needles

100328
currently out of stock
€89.00
incl. tax, plus shipping Shipping excluded

 

Blunt single-use cannula for professionals

JBP Nano Cannula 22G × 50 mm with matching 21G pre-puncture needles

The JBP Nano Cannula 22G × 50 mm is a sterile, blunt microcannula for professional use in medical and aesthetic settings. The 22G version combines a 50 mm shaft length with an Ultra-Thin-Wall design and is intended for single use.

Each pack contains 24 blunt 22G × 50 mm microcannulas and 24 matching 21G × 25.4 mm pre-puncture needles. Use is restricted to qualified professionals and must follow the manufacturer’s instructions for use.

Enlarged drawing; positions are explained in the legendActual size, based on a 50 mm shaft length
Technical drawing of the JBP Nano Cannula: hub, 22G cannula shaft with 50 mm length, and blunt tip 50 mm A A B 123
  • Hub
  • Cannula shaft 22G, 50 mm
  • Blunt tip, see detail B

Ruler below the cannula: marks every 1 mm, long marks every 10 mm. The displayed size depends on the screen and zoom level.

Ø 0.70

Section A–A22G corresponds to the nominal metric size of 0.70 mm. The wall follows the Ultra-Thin-Wall principle; wall thickness is shown schematically and not to scale.

Detail BBlunt, rounded tip, greatly enlarged and shown schematically. The manufacturer’s specifications are authoritative for the tip geometry.

Technical data

Dimensions in mm
Product name
JBP Nano Cannula
Reference
100328
Origin
Made in Korea
Size
22G
Length
50 mm
Pre-puncture needle
21G × 25.4 mm
Wall type
Ultra-Thin Wall
Sterilisation
EO-sterilised
Configuration + contents
24 × 22G × 50 mm + 24 × 21G × 25.4 mm
Use
Single use
CE marking
CE 0068 (according to product labelling)
Storage
store at room temperature; protect from moisture and direct sunlight

Schematic drawing based on the product data; hub simplified. The manufacturer’s labelling and instructions for use are authoritative.

Pack contents: 24 cannulas, 24 pre-puncture needles

The pack contains 24 sterile blunt 22G × 50 mm microcannulas and 24 corresponding 21G × 25.4 mm pre-puncture needles. Both components are individually sterile-packed and intended for single use.

Why a pre-puncture needle is supplied with each cannula

  1. Pre-puncture needle 21G × 25.4 mmIt is used to prepare a suitable entry opening for the blunt microcannula.
  2. Blunt microcannula 22G × 50 mmThe microcannula is then introduced through the prepared access point.

The supplied 21G pre-puncture needle is matched to the 22G microcannula. Technique and procedure must follow the manufacturer’s instructions for use.

24 ×blunt microcannula 22G × 50 mm
24 ×pre-puncture needle 21G × 25.4 mm

22G in size comparison

Gauge is a size designation related to the outer diameter: as the gauge number increases, the cannula becomes thinner. 22G corresponds to the nominal metric size of 0.70 mm.

Outer diameters shown to relative scale

0.1 mm

25G compared with 22G

Outer diameter, nominal
0.50 mm
Difference from 22G
−0.20 mm
External cross-sectional area
0.51×

Gold area: 22G, this cannula. Dashed outline: the selected comparison size. Nominal metric sizes follow the common gauge designation (ISO 9626), rounded and greatly enlarged. The actual inner diameter also depends on the wall design.

Ultra-Thin Wall: thin wall and potentially larger inner lumen

Ultra-Thin Wall refers to a particularly thin cannula wall. With the same outer diameter, a thinner wall can allow a larger inner diameter.

For illustration, the Hagen–Poiseuille law can be used for idealised laminar flow in a cylindrical capillary: at the same pressure and length, volumetric flow increases with the fourth power of the inner radius. This is a physical model, not a performance claim for this cannula.

Physical model: inner diameter and flow

Longitudinal section of a cannula with flow velocity profile; the wall becomes thinner and the inner lumen larger
+32 %Lumen area versus reference model
+75 %Volumetric flow versus reference model, idealised
Q ∝ r⁴Hagen–Poiseuille, laminar flow

Illustrative physical calculation model. The freely selectable percentage is an example and is not a manufacturer specification for the inner diameter, flow or injection force of this cannula. Real materials such as viscoelastic gels, as well as the syringe and connector, can substantially alter actual flow and pressure behaviour.

Before each use

Use is restricted to appropriately trained and qualified professional personnel. The cannulas are intended for single use only; reuse or re-sterilisation is not permitted.

Check before use

0 of 4 checked

Checklist for orientation only; no entries are stored. The manufacturer’s instructions for use are authoritative.

Labelling information

  • EO-sterilisedSterilised with ethylene oxide. Sterility applies only if the individual pack is undamaged and within the stated shelf life.
  • Single useFor single use only; do not reuse.
  • Do not re-steriliseRe-sterilisation is not permitted.
  • CE markingThe four-digit number identifies the notified body involved in the conformity assessment.

Symbols are shown schematically in line with ISO 15223-1. The labelling on the packaging is authoritative.

Frequently asked questions

What is the JBP Nano Cannula 22G × 50 mm?

The JBP Nano Cannula 22G × 50 mm is a sterile, blunt microcannula for professional use by qualified personnel. It is intended for single use.

How many cannulas are included in one pack?

One pack contains 24 sterile blunt 22G × 50 mm microcannulas and 24 matching 21G × 25.4 mm pre-puncture needles.

What is the pre-puncture needle used for?

A pre-puncture needle is used to create a suitable entry point for a blunt microcannula. The blunt cannula is then inserted through this opening. The diameter of the pre-puncture needle must be compatible with the microcannula; matching pre-puncture needles are included in the pack.

What does 22G mean?

22G is a gauge size designation and corresponds to the nominal metric size of 0.70 mm. Higher gauge numbers indicate smaller outer diameters. The inner diameter also depends on the wall design.

Is the JBP Nano Cannula sterile?

Yes. According to the packaging, the cannulas are EO-sterilised. Sterility applies only if the individual packaging is undamaged and within the stated shelf life.

Can the cannula be used more than once?

No. The JBP Nano Cannula is a single-use product. Reuse or re-sterilisation is not permitted.

Who is the JBP Nano Cannula intended for?

The product is intended exclusively for trained, qualified professional personnel. Use requires appropriate specialist knowledge, suitable hygiene standards and compliance with the manufacturer’s instructions.

For professional users: The information describes the product and does not replace the manufacturer’s instructions for use or professional assessment in the individual case.

Manufacturer:

Feel Tech Co., Ltd.

3, 4 Floor, Standard Factory 2-dong

15, Jayumyeok2-gil

Gunsan-si, Jeollabuk-do

Korea

EU Representative:

CMC Medical Devices & Drug S.L.

C/Horacio Lengo N 18

CP 29006 Málaga

Spain

Customers who bought this product also bought:

Product added to wishlist
Product added to compare.
group_work Cookie consent