SERVOspin Evolve benchtop centrifuge – 6×15 ml angle rotor
- Quiet benchtop centrifuge with 54° angle rotor, 6×15 ml
- Speed: 300–5000 rpm; max. RCF: up to 2,600 g
- Digital time/speed preselection, RCF display
- Brushless motor, imbalance control
- Electronic lid lock
- Scope of delivery: Rotor & adapter set
- Compliance: CE-marked IVD according to manufacturer's specifications
- Warranty: 24 months
- Note: For professional users only
SERVOspin Evolve – controlled centrifugation in a compact format
The SERVOspin Evolve is designed for smaller sample series in medical practices and laboratories. Its 54° fixed-angle rotor holds six tubes up to 15 ml; speed and run time can be set digitally and saved in two programs.
- 300–5,000 rpm and a maximum of 2,600 × g
- RCF display, two program memories and continuous operation
- Brushless motor, imbalance control and electronic lid lock
Key parameters at a glance
The operating range covers typical low-speed applications. The required settings always depend on the tube system used and its instructions for use.
For traceable workflows
Speed, RCF and time must be considered together. The SERVOspin Evolve supports the controlled implementation of specified centrifugation parameters but does not replace the protocol supplied by the tube manufacturer.
Check the tube specifications
Use the RCF, run time, fill volume and permitted rotor type stated in the instructions for use.
Set speed and time
Enter the values digitally and save frequently used settings to a program key.
Check the RCF value
The display can be switched between speed and the calculated RCF value.
Designed for day-to-day practice and laboratory use
Compact footprint
At 30 × 24 × 18 cm, the unit requires little bench space and weighs 5.2 kg.
Quiet operation
According to the manufacturer, the brushless, vibration-damped motor reaches approximately 56 dB at full load.
Integrated safety functions
Imbalance control, internal diagnostics and electronically monitored lid locking support safe operation.
Supplied ready for setup
The 54° fixed-angle rotor and adapter set are included.
Position within PRP workflows
The SERVOspin Evolve can be used as a technical aid when centrifuging compatible PRP tubes. The tube, rotor, fill volume, RCF and run time must be coordinated in accordance with the applicable instructions for use.
The centrifuge itself has no therapeutic intended purpose and makes no statement regarding the clinical efficacy of a processed product.
- Six rotor positions for smaller sample series
- RCF display for technical monitoring
- Storable settings for recurring workflows
- For use by qualified professional personnel only
Technical data
| Device category | Low-speed benchtop centrifuge |
|---|---|
| Rotor | 54° fixed-angle rotor |
| Capacity | 6 × 15 ml |
| Speed | 300–5,000 rpm, 10 rpm increments |
| Maximum RCF | 2,600 × g |
| Timer | 30 seconds to 99 minutes or continuous operation |
| Program memory | 2 freely assignable programs |
| Motor | Brushless and vibration-damped |
| Operating noise | Approx. 56 dB at full load |
| Safety functions | Lid lock, imbalance control, internal diagnostics and emergency opening in the event of a power failure |
| Dimensions | 30 × 24 × 18 cm (L × W × H) |
| Weight | 5.2 kg |
| Power supply | 100–240 V, 50/60 Hz |
| Power consumption | 70 W |
| WEEE registration number | DE74434443 |
| Warranty | 24 months |
Scope of delivery
- SERVOspin Evolve benchtop centrifuge
- 54° fixed-angle rotor for 6 × 15 ml
- Adapter set
- Operating documents
Instructions for users
- For professional users only
- Read the operating instructions before commissioning
- Always load tubes symmetrically and with equal weight
- Check the rotor and rotor chamber regularly for residue or damage
Frequently asked questions
The answers refer to the technical properties of the unit. The manufacturer's documentation and the specifications of the tube system used remain decisive.
How many tubes can be centrifuged at the same time?
The fixed-angle rotor has six positions for tubes up to 15 ml. Smaller tubes can be used with suitable adapters.
Can frequently used settings be saved?
Yes. Two freely assignable program keys are available for recurring combinations of speed and run time.
Can the RCF value be shown directly?
Yes. A key combination switches the display between speed and the calculated RCF value. Direct RCF programming is not stated in the available manufacturer information.
Is the SERVOspin Evolve specifically intended for PRP?
The SERVOspin Evolve is a low-speed benchtop centrifuge for sample centrifugation. It can be integrated into PRP workflows using suitable tubes and the corresponding parameters, but it has no therapeutic intended purpose of its own.
Is this a Class IIa medical device?
No. According to the manufacturer, the SERVOspin Evolve is a Class A in vitro diagnostic medical device under the IVDR. This classification must be distinguished from MDR Class IIa.
How loud is the centrifuge?
The manufacturer specifies an operating noise level of approximately 56 dB at full load.
Related information on prpmed.de
Note: Use only in accordance with the operating instructions, intended purpose and specifications of the tubes employed. Subject to technical changes and errors.
GPSR – General Product Safety Regulation (EU) 2023/988
Responsible economic operator according to GPSR (distributor)
servoprax GmbH
Am Marienbusch 9, 46485 Wesel, Germany
Tel. +49 281 95283-0 · Fax +49 281 56071 · [email protected]